Need for Discontinued OWW Knee

Ted Muilenburg

Description

Title:

Need for Discontinued OWW Knee

Creator:

Ted Muilenburg

Date:

6/14/2013

Text:

I have a congenital PFFD L/AK patient who uses the OWW, 3 ¼ left, Exo Knee,
with the hydraulic unit. Marvel Model 16, FRP-00325L. With that type of
knee we are able to carve out the wood and bond the small distal end of her
socket just anterior and distal to the knee bolt. I know of no Endo knees
that will work and cosmesis is very important to her. If anyone still has a
new knee set-up like that I can purchase, even close to that size, it would
be greatly appreciated.

 Sincerely,
Ted Muilenburg, C.P.FAAOP
Muilenburg Prosthetics Inc.
3900 La Branch
Houston, TX. 77004
713-524-3949