I have intercepted a noise issue with a fairly new CRO Walker. Our
design is fairly conventional with scalloped walls for
vertical interlocking, no reinforcing struts, Aliplast interface,
3/16copolymer, and a four strap Velcro closure system. I believe
frontal plane rotational movement may be the culprit, but still don't
have resolution of the problem. We added a test sleeve of nylon hosiery
between the two halves, but this did not help. We also trimmed the
anterior Aliplast away in the overlap areas and tried powder. Still no
improvement. We have not tried any form of lubricant. Any ideas will be
appreciated.
Thank you.
Wil Haines, CPO
MaxCare Bionics
Avon, IN 46123
********************
To unsubscribe, send a message to: <Email Address Redacted> with
the words UNSUB OANDP-L in the body of the
message.
If you have a problem unsubscribing,or have other
questions, send e-mail to the moderator
Paul E. Prusakowski,CPO at <Email Address Redacted>
OANDP-L is a forum for the discussion of topics
related to Orthotics and Prosthetics.
Public commercial postings are forbidden. Responses to inquiries
should not be sent to the entire oandp-l list. Professional credentials
or affiliations should be used in all communications.
I have intercepted a noise issue with a fairly new CRO Walker. Our
design is fairly conventional with scalloped walls for
vertical interlocking, no reinforcing struts, Aliplast interface,
3/16copolymer, and a four strap Velcro closure system. I believe
frontal plane rotational movement may be the culprit, but still don't
have resolution of the problem. We added a test sleeve of nylon hosiery
between the two halves, but this did not help. We also trimmed the
anterior Aliplast away in the overlap areas and tried powder. Still no
improvement. We have not tried any form of lubricant. Any ideas will be
appreciated.
Thank you.
Wil Haines, CPO
MaxCare Bionics
Avon, IN 46123
********************
To unsubscribe, send a message to: <Email Address Redacted> with
the words UNSUB OANDP-L in the body of the
message.
If you have a problem unsubscribing,or have other
questions, send e-mail to the moderator
Paul E. Prusakowski,CPO at <Email Address Redacted>
OANDP-L is a forum for the discussion of topics
related to Orthotics and Prosthetics.
Public commercial postings are forbidden. Responses to inquiries
should not be sent to the entire oandp-l list. Professional credentials
or affiliations should be used in all communications.
Citation
Wil, “CRO Walker Squeaking,” Digital Resource Foundation for Orthotics and Prosthetics, accessed November 6, 2024, https://library.drfop.org/items/show/234358.