MAS socket rotation difficulties

Jennifer Lee, CO

Description

Title:

MAS socket rotation difficulties

Creator:

Jennifer Lee, CO

Date:

11/4/2005

Text:

We are fitting a AK amputee with a MAS socket. So far, when we have
him walk in his test socket---the prosthesis internally rotates. We
have checked the placement of the ear on his ischial, ramal complex,
trim lines, etc. yet cannot come up with a reason why the socket is
rotating and it always internally rotates vs. external rotation. We
have also fit some other patients with the MAS system successfully and
(of course) without this problem. Any suggestions?

Jennifer Lee, CPO

                          

Citation

Jennifer Lee, CO, “MAS socket rotation difficulties,” Digital Resource Foundation for Orthotics and Prosthetics, accessed November 24, 2024, https://library.drfop.org/items/show/225722.