Recent Advances in Below-Knee Prosthetics

A. Bennett Wilson, Jr. *

Description

http://www.oandplibrary.org/al/pdf/1969_02_001.pdf
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-01.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-02.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-03.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-04.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-05.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-06.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-07.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-08.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-09.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-10.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-11.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-12.jpg
http://www.oandplibrary.org/al/images/1969_02_001/69autumn-13.jpg

Title:

Recent Advances in Below-Knee Prosthetics

Creator:

A. Bennett Wilson, Jr. *

Page Number(s):

1 - 12

Volume:

13

Issue:

2

Text:

View as PDF

with original layout

Recent Advances in Below-Knee Prosthetics

A. Bennett Wilson, Jr. *

The concept of constructing a below-knee prosthesis with side joints and a thigh lacer was set forth by the Dutch surgeon Verduin in 1696 (Fig. 1) and followed universally until the advent of the patellar-tendon-bearing prosthesis in the late 1950's. Although other innovations such as contact over the distal end of the stump, suction suspension, and "muley" sockets were introduced from time to time, they were never widely used, possibly because principles governing their use were not set forth in a systematic manner.


Fig. 1. Verduin leg (1696). From MacDonald, J., Amer.J. Surg., 1905.


In 1957, the predecessor of CPRD, the Advisory Committee on Artificial Limbs, encouraged the University of California at Berkeley to study the problems of the below-knee amputee and to improve the then current management practices. As a result, some of the leading prosthetists in this country were invited to Berkeley later in 1957 for the express purpose of examining in detail the prosthetics practices for BK amputees and rationales for those practices. An analysis of the findings of that conference led to the development of the patellar-tendon-bearing prosthesis, known now as the PTB prosthesis.

The original version of the PTB prosthesis was a plastic laminate socket which was formed over a modified plaster-of-Paris model of the stump, and which contained a soft inner liner that contacted the entire surface of the stump. The major weight was borne by the medial flares of the tibia and the patellar tendon. No knee joints or thigh corsets were used, suspension being effected by a fabric strap around the thigh just above the femoral condyles (Fig. 2).


Fig. 2. Cutaway view of the original patellar-tendon-bearing (PTB) prosthesis.


The PTB concept was offered in formal education programs in this country and gradually gained acceptance, so that by 1961 slightly more than half of the below-knee prostheses provided in the United States were of that type. The concept also has been accepted widely in other countries, and the PTB now is generally considered to be the standard prosthesis for below-knee amputations.

In recent years, research groups and individual prosthetists have introduced improvements to the basic concept. This article describes the advanced practices in the management of the below-knee amputee that have been developed since the introduction of the PTB prosthesis.

The Hard Socket

The original PTB socket design called for a lining of leather or Naugahyde backed by sponge rubber. Perspiration caused problems in many instances, however, because Naugahyde does not "breathe" and leather deteriorates rapidly in the presence of sweat. This problem prompted some prosthetists to eliminate the liner, and the "hard" PTB socket has become increasingly popular.

The PTS Socket

The suspension strap for the PTB prosthesis, as designed originally, was usually satisfactory, but there were enough dissatisfied amputees to prompt a number of prosthetists to seek improved suspension methods. In addition to developing different strap designs (Fig. 3) , several groups experimented with new configurations for the proximal border of the socket. The research team at Nancy, France, introduced the "prothese tibiale a emboitage supracondylien," popularly known as the PTS, in which the proximal border extends above the patella and the femoral condyles (Fig. 4), thus holding the socket on the stump. This concept was introduced into the United States by Nitschke and Marschall and the PTS prosthesis is being used at an increasing rate in the United States. The technique may be used with or without a liner. Hamontree , in reporting his experiences with 94 cases, noted that, although he believed that the majority of the patients could have been satisfied with the original version of the PTB, a certain percentage could have been successfully fitted only with the PTS version.


Fig. 3. Left, continuous-strap suspension arranged in a figure eight with Velcro for adjustment; right, anterior view of two inverted V-straps looped through a ring and attached inside a hard socket close to the brim.



Fig. 4. A right, below-knee stump and the amputee wearing a PTS-socket prosthesis.


Wedge Suspension Socket

Another attempt to improve upon the strap type of suspension resulted in the KBM (Kondylen Bettung Munster) prosthesis , in which a small wedge is inserted between the proximal area of the socket and the area of the stump along the medial condyles of the femur (Fig. 5). Developed at the University of Munster, this concept was introduced into the United States by Fillauer and is now known as the supracondylar-wedge suspension system. The wedge system may be used with or without a socket liner, but generally no liner is used.


Fig. 5. The supracondylar-wedge suspension method.


Air-Cushion Socket

In an effort to develop a socket that would permit the stump to bear the optimum amount of the weight load over its distal end, Wilson and his associates designed and developed the "air-cushion socket" (Fig. 6), which reduces the magnitude of the vertical components of weight-bearing forces at other points on the stump.


Fig. 6. Cutaway view of the air-cushion socket.


The air-cushion PTB consists of an elastic inner sleeve (stockinet impregnated with silicone rubber) suspended from the level of the tibial tubercle in a rigid outer shell that is closed distally. Stump support is provided by the tension of the sleeve itself and by the compression of the air in the chamber between the inner sleeve and outer cap.

Trials in the United States, Denmark, and Yugoslavia have shown that the air-cushion version of the PTB is particularly useful for patients with very sensitive stumps. In fact, there appear to be few, if any, contraindications to the use of the air-cushion socket, the only disadvantages being that slightly more time is required to fabricate the socket and that few modifications can be made after it has been fabricated.

Porous Socket

In seeking ways to alleviate the problems caused by perspiration, the U. S. Army Medical Biomechanical Research Laboratory developed a porous plastic laminate. Conventional epoxy resins and filler materials are used in the fabrication, but special care must be taken in controlling the proportions of the ingredients and in curing. The first porous laminates developed by AMBRL were satisfactory for upper-extremity sockets, but they were not strong enough for routine use in lower-extremity sockets. Subsequently, the technicians developed a fabrication technique using epoxy resins that overcame the major shortcomings of the earlier laminates. New York University, after studying 20 children and young adults, reported that the porous-laminate socket appeared to be a "significant and worthwhile addition" to below-knee prosthetics specifically and to limb prosthetics generally. There were fewer problems with perspiration, and skin eruptions were ameliorated. In addition, the prostheses with porous-laminate sockets weighed less. When perspiration was a major problem, the two disadvantages cited-slightly increased fabrication time and greater difficulty in maintaining socket cleanliness-were far outweighed by the advantages.

Because most of the innovations to the original PTB design are not mutually exclusive, it was possible to develop a chart showing the combinations of features that can be used to devise a below-knee prosthesis that best meets the needs of the individual patient (Fig. 7).


Fig. 7.


Casting Methods

The method for obtaining a model of the stump for fabrication of the PTB socket, as described in the original manuals, consisted of wrapping the stump with plaster-of-Paris bandages, shaping the wrap with the fingers, and subsequently modifying the male mold produced from the female cast, or wrap. Any number of attempts have been made to devise a procedure that would require less skill. One such method that has been accepted by many prosthetists is the sling-casting, or suspension-casting, technique developed by Hampton (Fig. 8).


Fig. 8. Ring and sock for suspension casting of the below-knee stump.


In the suspension-casting technique, the stump is wrapped while it is held in a vertical position that simulates weight-bearing during standing. Felt patches to provide relief for sensitive areas of the stump can be applied directly to the stump, and a minimum amount of modification is necessary, although the need for modification is not eliminated entirely.

Research workers and clinicians have been searching for years for a material that will enable the prosthetist to form a socket directly over the stump, thereby eliminating the need for plaster wraps and male molds. Experience with a synthetic rubber, Polysar* X-414, has shown that this material definitely has a place in the fabrication of sockets. Temporary, or provisional, below-knee prostheses consisting of a synthetic-balata socket and pylon-type components are proving to be useful. Because it becomes pliable at temperatures easily tolerated by the skin, synthetic balata can be applied directly over the stump. Extruded tubing of various diameters with walls 1/4-in. thick is available. A piece of tubing slightly smaller in diameter than the stump is heated in water to about 160 deg F, then forced over the stump, which has been padded in appropriate areas (Fig. 9). To give proper shape to the socket, a length of pressure-sensitive tape, 1 in. wide, is wrapped over the outside, and final forming is carried out manually. To provide total contact, the distal end is filled with "foam-in-place" silicone. The socket is easily mounted on a pylon unit for use as a temporary prosthesis, or a more permanent one if desired. The prosthesis can be given a natural appearance by applying and shaping semirigid blocks of Koroseal "Spongex"* (Fig. 10). Contours of the socket can be changed at any time by heating the area with a heat gun and reshaping it manually.*


Fig. 9. Top, application of socket tube to the stump; bottom, trimming of socket brim prior to final molding.



Fig. 10. Foam blocks for fitting over pylon and socket.


Time of Fitting

During the past decade, the advantages of fitting a prosthesis as soon after amputation as possible have been demonstrated repeatedly. Goldner and his associates demonstrated that "early" fitting-that is, providing the patient with a temporary prosthesis as soon as the wound has healed rather than waiting for a maximum amount of shrinkage to take place-could drastically reduce time and costs of rehabilitation. Even more dramatic results have been obtained by fitting artificial limbs immediately after surgery, especially with below-knee amputees (Fig. 11).


Fig. 11. Schematic cross section showing the major elements of a prosthesis as applied immediately following surgery to a below-knee amputee. The suture line, silk dressing, and drain are not shown. The fluffed gauze does not extend beyond the area indicated in "A." Inset: A below-knee amputee fitted with the immediate postsurgical prosthesis.


The technique of immediate postsurgical fitting was originated in France by Berlemont, was carried further by Weiss in Poland, and, after a considerable experimentation period in the United States, is now being taught routinely in the prosthetics education programs in this country. The technique consists of applying a rigid dressing over the stump and attaching an adjustable pylon and foot. Standing and ambulation is begun as soon as the patient's condition permits. For young, otherwise healthy patients, some ambulation can begin on the day following amputation.

Usually the rigid dressing is left in place until the wound has healed and the sutures can be removed-about 10-14 days postoperatively. A second rigid dressing is provided for another 10- to 14-day period, at which time a "permanent," or definitive, limb can be provided. The advantages of immediate postsurgical fitting include reduction of edema, less pain, shorter periods of hospitalization and therapy, and fewer contractures. The technique has become standard practice in many centers with trained teams.

Hardware

To make early fitting and immediate postsurgical fitting easier, a number of adjustable pylons have been developed. Those currently available are shown in Fig. 12. Some of their characteristics are given in Table 1. These units are strong enough and light enough for extended usage with or without some sort of cosmetic cover. A number of approaches to cosmetic treatment such as the use of Spongex, mentioned above, have been offered, but none have been accepted widely by prosthetists. Work on this problem is continuing.


Fig. 12. Below-knee pylon-type prostheses that can be used for fitting immediately after surgery. A, Hosmer Postoperative Pylon; B, Northwestern Pylon (Hosmer); C, Veterans Administration Prosthetics Center (VAPC) "Standard" Pylon; D, Canadian "Instant" Prosthesis (Hosmer); E, United States Manufacturing Co. Pylon; F, Finnie-Jig (Arthur Finnieston Co.). Metal straps for attachment to a plaster-of-Paris socket are available, but not shown. Courtesy of Veterans Administration Prosthetics Center.




Education and Research Needs

At the December 1968 "Symposium on Below-Knee Prosthetics", sponsored by the Committee on Prosthetics Research and Development, a number of suggestions for improving prosthetics education and practice were offered.

  1. The body of knowledge about BK prosthetics that has been developed in recent years should be made available to practicing prosthetists and other clinicians.
  2. All institutions offering prosthetics-education courses should include the information presented at the symposium in their curricula.
  3. Opportunities for continuing education, such as postgraduate-type courses for clinic teams in the latest prosthetics techniques, should be provided.
  4. Additional manuals and other instructional materials should be prepared. In addition, a central group that would be responsible for the orderly preparation and dissemination of technical information is needed.
  5. Current research efforts in BK prosthetics should be continued, but with emphasis placed on the development of a truly refined theory of fitting.

Because most of the recent improvements to the design of the below-knee socket, especially in suspension techniques, have been accomplished by practicing prosthetists, there is little need for the research centers to devote their time to developing additional improvements. On the other hand, there is very little knowledge about the basic principles underlying optimum fitting of prostheses. Therefore, the research centers should be encouraged to obtain basic information about the effects of pressure and shear forces on tissues, and to more clearly indicate the biomechanical forces required in the various phases of walking. Following that work, methods by which those principles could be put into practice should be developed, including the use of hydrostatic sockets and other methods that might provide automatic adjustment.

As a result of these suggestions, a pilot course in advanced below-knee prosthetics practices was held at Northwestern University (see "News and Notes") on August 4-13, 1969, for prosthetist instructors from the University of California at Los Angeles, New York University, and Northwestern University. The University Council on Prosthetics Education is now developing a curriculum for short-term postgraduate courses in below-knee prosthetics. The advanced techniques will also be offered in regular courses in below-knee prosthetics.

References:

  1. The American Academy of Orthopaedic Surgeons, Inc., Historical development of artificial limbs, Chap. 1 in Orthopaedic appliances atlas, Vol. 2, J. W. Edwards, Ann Arbor, Mich., 1960.
  2. Burgess, Ernest M., The below-knee amputation, Inter-Clinic Inform. Bull., 8:4:1-22, January 1969.
  3. Burgess, Ernest M., and Joseph H. Zettl, Amputations below the knee, Artif. Limbs, 13:1:1-12, Spring 1969.
  4. Burgess, Ernest M., Joseph E. Traub, and A. Bennett Wilson, Jr., Immediate postsurgical prosthetics in the management of lower extremity amputees, TR 10-5, Prosthetic and Sensory Aids Service, Veterans Administration, Washington, D. C, April 1967.
  5. Caldwell, Jack L., Inverted V-strap suspension for PTB prosthesis, Artif. Limbs, 9:1:23-26, Spring 1965.
  6. Committee on Prosthetics Research and Development, Below-knee prosthetics, A report of a symposium, National Academy of Sciences, Washington, D. C, December 1968.
  7. Committee on Prosthetics Research and Development, Immediate postsurgical fitting of prostheses, A report of a workshop, National Academy of Sciences, Washington, D. C, May 1968.
  8. Compere, Clinton L., Early fitting of prostheses following amputation, Surg. Clin. N. Amer., 48:1:215-226, February 1968.
  9. Dolan, Clyde M. E., The Army Medical Biomechanical Research Laboratory porous laminate patellar-tendon-bearing prosthesis, Artif. Limbs, 12:1:25-34, Spring 1968.
  10. Fillauer, Carlton, Supracondylar wedge suspension of the P T.B. prosthesis, Orth. and Pros., 22:2:39-44, June 1968.
  11. Goldner, J. Leonard, Frank W. Clippinger, and Bert R. Titus, Use of temporary plaster or plastic pylons preparatory to fitting a permanent above knee or below knee prosthesis, Final Report of Project RD-1363-M, Duke University Medical Center, Durham, N. C, circa 1967.
  12. Hamontree, Sam E., Howard J. Tyo, and Snowdon Smith, Twenty months experience with the "PTS", Orth. and Pros., 22:1:33-39, March 1968.
  13. Hampton, Fred, Suspension casting for below knee, above-knee, and Syme's amputations, Artif. Limbs, 10:2:5-26, Autumn 1966.
  14. Hill, James T., Henry Mouhot, and Robert E. Plumb, Manual for preparation of a porous PTB socket with soft distal end, Tech. Rep. 6804, U. S. Army Medical Biomechanical Research Laboratory, Washington, D. C, May 1968.
  15. Kuhn, G. G., S. Burger, R. Schettler, and G. Fajal, Kondylen Bettung Munster am Unter-schenkel Stumpf, "KBM-Prothese," Atlas d'Appareillage Prothetique et Orthopedique, No. 14, 1966.
  16. Litt, Bertram D., and LeRoy Wm. Nattress, Jr., Prosthetic services USA-1961, American Orthotics and Prosthetics Association, Washington, D. C, October 1961.
  17. Lower-Extremity Amputee Research Project, Minutes of symposium on BK prosthetics, University of California, Berkeley, April 1957.
  18. Marschall, Kurt, and Robert Nitschke, Principles of the patellar tendon supra-condylar prosthesis, Orthop. Pros. Appl. J., 21:1:33-38, March 1967.
  19. Marschall, Kurt, and Robert Nitschke, The P.T.S. prosthesis (Complete enclosure of patella and femoral condyles in below knee fittings), Orthop. Pros. Appl. J., 20:2:123-126, June 1966.
  20. Pierquin, L., G. Fajal, and J. M. Paquin, Prothese tibiale a emboitage supracondylien, Atlas d'Appareillage Prothetique et Orthopedique, No. 1, January 1964.
  21. Plumb, Robert E., and Fred Leonard, Patella-tendon-bearing below-knee porous socket with soft Silastic distal end, Tech. Rep. 6311, U S. Army Medical Biomechanical Research Laboratory, Washington, D. C, June 1963.
  22. Radcliffe, C. W., and J. Foort, The patellar-tendon-bearing below-knee prosthesis, Biomechanics Laboratory, University of California, Berkeley and San Francisco, 1961.
  23. The Staff of the Prosthetics Research Group, Biomechanics Laboratory-University of California, Manual of below knee prosthetics, The Regents of the University of California, November 1959.
  24. The Staff, Veterans Administration Prosthetics Center, Direct forming of below-knee patellar-tendon-bearing sockets with a thermoplastic material, Orth. and Pros., 23:1:36-61, March 1969.
  25. Wilson, L. A., E. Lyquist, and C. W. Radcliffe, Air-cushion socket for patellar-tendon-bearing below-knee prosthesis, Tech. Rep. 55, Department of Medicine and Surgery, Veterans Administration, Washington, D. C, May 1968.

Reference
6. Committee on Prosthetics Research and Development, Below-knee prosthetics, A report of a symposium, National Academy of Sciences, Washington, D. C, December 1968.
Reference
7. Committee on Prosthetics Research and Development, Immediate postsurgical fitting of prostheses, A report of a workshop, National Academy of Sciences, Washington, D. C, May 1968.
Reference
7. Committee on Prosthetics Research and Development, Immediate postsurgical fitting of prostheses, A report of a workshop, National Academy of Sciences, Washington, D. C, May 1968.
References
2. Burgess, Ernest M., The below-knee amputation, Inter-Clinic Inform. Bull., 8:4:1-22, January 1969.
3. Burgess, Ernest M., and Joseph H. Zettl, Amputations below the knee, Artif. Limbs, 13:1:1-12, Spring 1969.
4. Burgess, Ernest M., Joseph E. Traub, and A. Bennett Wilson, Jr., Immediate postsurgical prosthetics in the management of lower extremity amputees, TR 10-5, Prosthetic and Sensory Aids Service, Veterans Administration, Washington, D. C, April 1967.
8. Compere, Clinton L., Early fitting of prostheses following amputation, Surg. Clin. N. Amer., 48:1:215-226, February 1968.
Reference
11. Goldner, J. Leonard, Frank W. Clippinger, and Bert R. Titus, Use of temporary plaster or plastic pylons preparatory to fitting a permanent above knee or below knee prosthesis, Final Report of Project RD-1363-M, Duke University Medical Center, Durham, N. C, circa 1967.
Footnote
Sockets of this material should not be left near radiators or in an abnormally warm environment, such as the interior of a closed automobile parked in sunlight on a warm day, because synthetic balata becomes pliable at temperatures as low as 120 deg F.
Footnote
B. F. Goodrich Co.
Reference
24. The Staff, Veterans Administration Prosthetics Center, Direct forming of below-knee patellar-tendon-bearing sockets with a thermoplastic material, Orth. and Pros., 23:1:36-61, March 1969.
Footnote
Registered trademark of Polymer Corporation Limited.
Reference
13. Hampton, Fred, Suspension casting for below knee, above-knee, and Syme's amputations, Artif. Limbs, 10:2:5-26, Autumn 1966.
Reference
9. Dolan, Clyde M. E., The Army Medical Biomechanical Research Laboratory porous laminate patellar-tendon-bearing prosthesis, Artif. Limbs, 12:1:25-34, Spring 1968.
Reference
21. Plumb, Robert E., and Fred Leonard, Patella-tendon-bearing below-knee porous socket with soft Silastic distal end, Tech. Rep. 6311, U S. Army Medical Biomechanical Research Laboratory, Washington, D. C, June 1963.
References
9. Dolan, Clyde M. E., The Army Medical Biomechanical Research Laboratory porous laminate patellar-tendon-bearing prosthesis, Artif. Limbs, 12:1:25-34, Spring 1968.
14. Hill, James T., Henry Mouhot, and Robert E. Plumb, Manual for preparation of a porous PTB socket with soft distal end, Tech. Rep. 6804, U. S. Army Medical Biomechanical Research Laboratory, Washington, D. C, May 1968.
21. Plumb, Robert E., and Fred Leonard, Patella-tendon-bearing below-knee porous socket with soft Silastic distal end, Tech. Rep. 6311, U S. Army Medical Biomechanical Research Laboratory, Washington, D. C, June 1963.
Reference
6. Committee on Prosthetics Research and Development, Below-knee prosthetics, A report of a symposium, National Academy of Sciences, Washington, D. C, December 1968.
Reference
25. Wilson, L. A., E. Lyquist, and C. W. Radcliffe, Air-cushion socket for patellar-tendon-bearing below-knee prosthesis, Tech. Rep. 55, Department of Medicine and Surgery, Veterans Administration, Washington, D. C, May 1968.
Reference
10. Fillauer, Carlton, Supracondylar wedge suspension of the P T.B. prosthesis, Orth. and Pros., 22:2:39-44, June 1968.
Reference
15. Kuhn, G. G., S. Burger, R. Schettler, and G. Fajal, Kondylen Bettung Munster am Unter-schenkel Stumpf, 'KBM-Prothese,' Atlas d'Appareillage Prothetique et Orthopedique, No. 14, 1966.
Reference
12. Hamontree, Sam E., Howard J. Tyo, and Snowdon Smith, Twenty months experience with the 'PTS', Orth. and Pros., 22:1:33-39, March 1968.
References
18. Marschall, Kurt, and Robert Nitschke, Principles of the patellar tendon supra-condylar prosthesis, Orthop. Pros. Appl. J., 21:1:33-38, March 1967.
19. Marschall, Kurt, and Robert Nitschke, The P.T.S. prosthesis (Complete enclosure of patella and femoral condyles in below knee fittings), Orthop. Pros. Appl. J., 20:2:123-126, June 1966.
Reference
20. Pierquin, L., G. Fajal, and J. M. Paquin, Prothese tibiale a emboitage supracondylien, Atlas d'Appareillage Prothetique et Orthopedique, No. 1, January 1964.
Reference
5. Caldwell, Jack L., Inverted V-strap suspension for PTB prosthesis, Artif. Limbs, 9:1:23-26, Spring 1965.
Reference
6. Committee on Prosthetics Research and Development, Below-knee prosthetics, A report of a symposium, National Academy of Sciences, Washington, D. C, December 1968.
Reference
16. Litt, Bertram D., and LeRoy Wm. Nattress, Jr., Prosthetic services USA-1961, American Orthotics and Prosthetics Association, Washington, D. C, October 1961.
References
22. Radcliffe, C. W., and J. Foort, The patellar-tendon-bearing below-knee prosthesis, Biomechanics Laboratory, University of California, Berkeley and San Francisco, 1961.
23. The Staff of the Prosthetics Research Group, Biomechanics Laboratory-University of California, Manual of below knee prosthetics, The Regents of the University of California, November 1959.
Reference
17. Lower-Extremity Amputee Research Project, Minutes of symposium on BK prosthetics, University of California, Berkeley, April 1957.
Reference
1. The American Academy of Orthopaedic Surgeons, Inc., Historical development of artificial limbs, Chap. 1 in Orthopaedic appliances atlas, Vol. 2, J. W. Edwards, Ann Arbor, Mich., 1960.
A. Bennett Wilson, Jr.
Executive Director, Committee on Prosthetics Research and Development, National Research Council, 2101 Constitution Ave., N. W., Washington, D.C. 20418.

Full Text PDF:

http://www.oandplibrary.org/al/pdf/1969_02_001.pdf

Figure 1:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-01.jpg

Figure 2:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-02.jpg

Figure 3:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-03.jpg

Figure 4:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-04.jpg

Figure 5:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-05.jpg

Figure 6:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-06.jpg

Figure 7:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-07.jpg

Figure 8:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-08.jpg

Figure 9:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-09.jpg

Figure 10:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-10.jpg

Figure 11:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-11.jpg

Figure 12:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-12.jpg

Figure 13:

http://www.oandplibrary.org/al/images/1969_02_001/69autumn-13.jpg

Citation

A. Bennett Wilson, Jr. * , “Recent Advances in Below-Knee Prosthetics,” Digital Resource Foundation for Orthotics and Prosthetics, accessed November 22, 2024, https://library.drfop.org/items/show/179734.